Environmental noise modelling, built UK-first

See soundbefore it'sbuilt.

AURIS is noise modelling software for acoustic consultants: ISO 9613-2:2024, CRTN, CRN, BS 5228 and BS 4142 in one fast, native app. Officially distributed by Polaris Acoustics.

ISO 9613-2:2024CRTNCRNBS 5228BS 4142
Scroll to model a site
01 / Draw

Start from a blank grid or a basemap.

Trace roads, railways, plant, buildings and barriers in a plan view that behaves like a drawing tool, not a spreadsheet.

  • Point, line, area, road and rail sources
  • Buildings, barriers, berms and ground regions
  • Terrain from survey points or imported grids
02 / Build

Raise the whole site in 3D.

Terrain, buildings and screening come to life in a real-time 3D view, so you can check the model the way a planning officer will see it.

  • Physically based 3D renderer
  • Terrain-following roads and rail
  • Façades, berms and barriers in place
03 / Calculate

Propagate every path, by the standard.

ISO 9613-2:2024 divergence, atmospheric absorption, ground effect and screening over and around obstacles, alongside native CRTN and CRN for transport.

  • Day and night periods, scenarios and time slices
  • Receptor levels traced back to every term
  • Multi-core solver that stays responsive
04 / Map

Turn results into report-ready noise maps.

Contour bands draped over the terrain, receptor levels in plan and 3D, and sheets you can drop straight into a planning report.

  • Contours at the receptor height you choose
  • Report sheets with legend, scale and north arrow
  • Results tables you can copy into Excel
The real application

Not a mock-up. This is AURIS.

Every screen below is the shipping desktop app, running a demonstration site. Plan, 3D, contours and results, all in one window.

AURIS plan editor showing a residential site with roads, a railway, an industrial unit and receptor levels in dBA AURIS 3D view of the demonstration site with terrain contours, buildings, roads, a bund and labelled receptor levels AURIS contours workspace with colour bands, levels and grid settings AURIS results table listing receptor levels by period

The plan editor: draw sources, buildings and barriers, then see receptor levels appear in place after each calculation.

Designed for consultants

Fast enough to model while you think.

Move a barrier and recalculate the receptors in seconds on a site like this one. The solver spreads work across every core and the 3D view follows the model as you build, so options get tested in the meeting, not after it.

Receptor levels labelled over interpolated noise contours in AURIS
Release discipline
120+

versions shipped, often several in a week.

Each one with published checksums and a packaged smoke test, delivered through the in-app updater.

Terrain

Real ground, real screening.

Survey points or grids become terrain that every path is cut against, with berms modelled as earthworks rather than walls.

Library

BS 5228 Annex C, built in.

474 plant entries, each read three independent ways from the standard and rebuilt byte for byte, ready to drop onto a site.

Reporting

Sheets that look finished.

Legends, scale bars, north arrows and your branding laid out for you, exported as PDF, SVG or PNG.

Why switch

Your survey kit is current. Is your model?

Most of a consultant's week is spent inside software designed for a different decade. AURIS starts from how the work is actually done, and from what a reviewer will ask to see.

What consultants put up withWhat AURIS does instead

A single number at each receptor, and a long afternoon if anyone asks where it came from.

Why this level? Any ISO 9613-2 receptor level opens up term by term: divergence, air, ground, screening, the sources that dominate and what changes if one goes.

Contour plots redrawn in another package before they are fit for a report.

Report sheets with legend, scale bar and north arrow, exported straight to PDF, SVG or PNG.

Validation promised in a brochure, without the cases, the tolerances or the misses.

The control examples, the tolerance and the one case that differs, published on this page.

Results that shift quietly between versions.

Frozen reference results: if a code change moves any of them, by any amount, the release stops.

Editing a site through dialog boxes and tables.

A plan editor that behaves like a drawing tool, with the 3D model a click away.

Methods

The standards UK consultants are asked for.

Implemented from the published texts, written up method by method, and checked against each standard’s own worked examples wherever it publishes them.

ISO 9613-2

Outdoor sound propagation, 2024 edition

Geometric divergence, atmospheric absorption, ground effect and barrier attenuation for industrial plant, fixed equipment and general sources, including lateral paths around obstacles.

Point, line, areaLateral screeningReflections
CRTN

Calculation of Road Traffic Noise

Native CRTN with flow, speed, percentage heavy vehicles, gradient and surface corrections, screening and angle of view, from 18-hour flows to night-time estimates.

LA10,18hFaçade correctionsNight estimates
CRN

Calculation of Railway Noise

Train classes, speeds and movements by period, track corrections and screening, worked through segment by segment to receptor levels.

Train classesTrack correctionsBy period
BS 5228

Construction and open sites

The Annex C plant library built in and verified, so construction noise predictions start from the levels the standard publishes.

Annex C libraryActivity levels
BS 4142

Industrial and commercial sound

Specific, rating and background levels side by side, with the context a BS 4142 assessment needs at each receptor.

Rating levelBackgroundDay and night
Validation

Show the working. Including the case that differs.

Acoustic software is only as good as its worst case, so here is ours. These are AURIS results for the ISO/TR 17534-3 control examples for ISO 9613-2, every octave band, against the published reference values.

ISO/TR 17534-3 control examples: AURIS difference from the reference, per octave band T01 to T18 lie within plus or minus 0.5 dB in every octave band; the largest is 0.27 dB (T08). T19 differs by 2.23 dB at 250 Hz, off the top of this scale, a documented difference between the 1996-based reference and the 2024 edition. +0.50 +0.25 0 −0.25 −0.50 ±0.5 dB result interval Difference from reference, dB T01 T01 · 63 Hz · −0.00 dB T01 · 125 Hz · −0.01 dB T01 · 250 Hz · −0.00 dB T01 · 500 Hz · +0.00 dB T01 · 1 kHz · +0.00 dB T01 · 2 kHz · −0.00 dB T01 · 4 kHz · −0.00 dB T01 · 8 kHz · −0.00 dB T02 T02 · 63 Hz · −0.00 dB T02 · 125 Hz · −0.01 dB T02 · 250 Hz · −0.01 dB T02 · 500 Hz · +0.00 dB T02 · 1 kHz · +0.00 dB T02 · 2 kHz · −0.00 dB T02 · 4 kHz · −0.00 dB T02 · 8 kHz · −0.00 dB T03 T03 · 63 Hz · −0.00 dB T03 · 125 Hz · −0.00 dB T03 · 250 Hz · +0.01 dB T03 · 500 Hz · +0.01 dB T03 · 1 kHz · +0.01 dB T03 · 2 kHz · −0.01 dB T03 · 4 kHz · −0.00 dB T03 · 8 kHz · −0.00 dB T04 T04 · 63 Hz · −0.00 dB T04 · 125 Hz · −0.01 dB T04 · 250 Hz · −0.01 dB T04 · 500 Hz · +0.00 dB T04 · 1 kHz · +0.01 dB T04 · 2 kHz · +0.00 dB T04 · 4 kHz · +0.00 dB T04 · 8 kHz · −0.01 dB T05 T05 · 63 Hz · +0.01 dB T05 · 125 Hz · −0.00 dB T05 · 250 Hz · −0.01 dB T05 · 500 Hz · −0.00 dB T05 · 1 kHz · +0.01 dB T05 · 2 kHz · +0.00 dB T05 · 4 kHz · −0.01 dB T05 · 8 kHz · −0.01 dB T06 T06 · 63 Hz · +0.00 dB T06 · 125 Hz · −0.01 dB T06 · 250 Hz · −0.00 dB T06 · 500 Hz · +0.01 dB T06 · 1 kHz · +0.00 dB T06 · 2 kHz · −0.00 dB T06 · 4 kHz · −0.01 dB T06 · 8 kHz · −0.01 dB T07 T07 · 63 Hz · +0.00 dB T07 · 125 Hz · −0.01 dB T07 · 250 Hz · −0.00 dB T07 · 500 Hz · +0.00 dB T07 · 1 kHz · +0.01 dB T07 · 2 kHz · +0.00 dB T07 · 4 kHz · +0.00 dB T07 · 8 kHz · −0.00 dB T08 T08 · 63 Hz · −0.20 dB T08 · 125 Hz · −0.25 dB T08 · 250 Hz · −0.00 dB T08 · 500 Hz · −0.27 dB T08 · 1 kHz · −0.23 dB T08 · 2 kHz · −0.17 dB T08 · 4 kHz · −0.12 dB T08 · 8 kHz · −0.08 dB T09 T09 · 63 Hz · −0.21 dB T09 · 125 Hz · −0.23 dB T09 · 250 Hz · −0.00 dB T09 · 500 Hz · −0.26 dB T09 · 1 kHz · −0.21 dB T09 · 2 kHz · −0.16 dB T09 · 4 kHz · −0.12 dB T09 · 8 kHz · −0.08 dB T10 T10 · 63 Hz · +0.08 dB T10 · 125 Hz · +0.02 dB T10 · 250 Hz · −0.07 dB T10 · 500 Hz · +0.05 dB T10 · 1 kHz · +0.11 dB T10 · 2 kHz · +0.15 dB T10 · 4 kHz · +0.11 dB T10 · 8 kHz · −0.01 dB T11 T11 · 63 Hz · −0.12 dB T11 · 125 Hz · −0.03 dB T11 · 250 Hz · +0.00 dB T11 · 500 Hz · −0.00 dB T11 · 1 kHz · −0.04 dB T11 · 2 kHz · −0.05 dB T11 · 4 kHz · −0.05 dB T11 · 8 kHz · −0.05 dB T12 T12 · 63 Hz · −0.23 dB T12 · 125 Hz · −0.11 dB T12 · 250 Hz · −0.02 dB T12 · 500 Hz · −0.01 dB T12 · 1 kHz · −0.09 dB T12 · 2 kHz · −0.12 dB T12 · 4 kHz · −0.12 dB T12 · 8 kHz · −0.12 dB T13 T13 · 63 Hz · −0.07 dB T13 · 125 Hz · −0.01 dB T13 · 250 Hz · +0.03 dB T13 · 500 Hz · +0.03 dB T13 · 1 kHz · −0.01 dB T13 · 2 kHz · −0.02 dB T13 · 4 kHz · −0.02 dB T13 · 8 kHz · −0.02 dB T14 T14 · 63 Hz · −0.07 dB T14 · 125 Hz · −0.03 dB T14 · 250 Hz · −0.00 dB T14 · 500 Hz · +0.03 dB T14 · 1 kHz · +0.02 dB T14 · 2 kHz · +0.01 dB T14 · 4 kHz · −0.00 dB T14 · 8 kHz · −0.01 dB T15 T15 · 63 Hz · −0.23 dB T15 · 125 Hz · −0.19 dB T15 · 250 Hz · −0.16 dB T15 · 500 Hz · −0.15 dB T15 · 1 kHz · −0.17 dB T15 · 2 kHz · −0.18 dB T15 · 4 kHz · −0.19 dB T15 · 8 kHz · −0.18 dB T16 T16 · 63 Hz · −0.05 dB T16 · 125 Hz · +0.01 dB T16 · 250 Hz · +0.02 dB T16 · 500 Hz · +0.01 dB T16 · 1 kHz · −0.01 dB T16 · 2 kHz · −0.01 dB T16 · 4 kHz · −0.01 dB T16 · 8 kHz · −0.01 dB T17 T17 · 63 Hz · −0.04 dB T17 · 125 Hz · +0.02 dB T17 · 250 Hz · +0.03 dB T17 · 500 Hz · +0.04 dB T17 · 1 kHz · −0.00 dB T17 · 2 kHz · −0.01 dB T17 · 4 kHz · −0.01 dB T17 · 8 kHz · −0.01 dB T18 T18 · 63 Hz · −0.00 dB T18 · 125 Hz · −0.00 dB T18 · 250 Hz · −0.03 dB T18 · 500 Hz · −0.05 dB T18 · 1 kHz · −0.07 dB T18 · 2 kHz · −0.06 dB T18 · 4 kHz · −0.05 dB T18 · 8 kHz · −0.05 dB T19 T19 · 63 Hz · +0.00 dB T19 · 125 Hz · −0.01 dB T19 · 250 Hz · +2.23 dB (off scale) T19 · 500 Hz · +0.01 dB T19 · 1 kHz · +0.01 dB T19 · 2 kHz · +0.00 dB T19 · 4 kHz · +0.01 dB T19 · 8 kHz · +0.01 dB T19 at 250 Hz: +2.23 dB, off scale
View the numbers
CaseScenarioLargest difference, dBResult
T01Hard Ground0.009Within ±0.5 dB
T02Mixed Ground0.008Within ±0.5 dB
T03Soft Ground0.009Within ±0.5 dB
T04Mixed Ground Zones0.012Within ±0.5 dB
T05Simplified Ground0.007Within ±0.5 dB
T06Variable Terrain0.011Within ±0.5 dB
T07Variable Terrain Simplified Ground0.011Within ±0.5 dB
T08Long Barrier0.272Within ±0.5 dB
T09Short Barrier0.264Within ±0.5 dB
T10Variable Terrain + Short Barrier0.148Within ±0.5 dB
T11Cube + Low Receiver0.118Within ±0.5 dB
T12Cube + High Receiver0.232Within ±0.5 dB
T13Prism + Low Receiver0.069Within ±0.5 dB
T14Variable Terrain + Prism0.065Within ±0.5 dB
T15Prism + High Receiver0.231Within ±0.5 dB
T16Three Buildings0.050Within ±0.5 dB
T17Three Buildings Alt S/R0.039Within ±0.5 dB
T18Complex Building Courtyard0.068Within ±0.5 dB
T19Variable Terrain + Reflective Barrier2.228Outside: documented edition difference
18/18

ISO/TR 17534-3 cases T01 to T18 within ±0.5 dB in every octave band, checked at every release

0.27 dB

largest difference among those cases (T08, 500 Hz)

0.085 dB

largest difference from a separate in-house solver across 15 benchmark scenarios

5,000+

automated tests across the engine, file handling and interface

T19, published rather than hidden

T19 differs by 2.23 dB at 250 Hz. The original reference table follows ISO 9613-2:1996 and leaves out a 250 Hz ground term that Formulae (26) and (27) of the 2024 edition admit. It stays in the suite as a documented diagnostic, untouched.

CRTN and CRN worked examples

CRTN Annex worked examples 2 to 18 and CRN Appendix A2 worked examples 2 to 14 run through the same code path you use, not a test copy of it. CRN is held to 0.11 dB mean and 0.35 dB worst-case error.

A second solver that cannot cheat

An independent implementation, written so it cannot import a line of AURIS code, recalculates ISO 9613-2 point, line and area sources, CRTN and CRN cases. The two agree to within 0.085 dB.

Results that do not drift

Seven reference scenes and their contour grids are frozen. Any change that moves a frozen result, by any amount, fails the release.

Method by method

Each method is checked two ways: against the worked examples its own standard publishes, and against a separate solver that shares no code with AURIS. Geometric divergence, atmospheric absorption, ground effect and barrier attenuation are compared term by term, not only as a final level.

MethodPublished examplesIndependent scenariosLargest differenceLimit applied
ISO 9613-2, point sourcesISO/TR 17534-3 T01 to T18, within ±0.5 dB3 of 3Below 0.000001 dB0.000001 dB
ISO 9613-2, line sourcesCovered by the independent solver3 of 30.085 dB0.05 to 0.1 dB
ISO 9613-2, area sourcesCovered by the independent solver3 of 30.012 dB0.05 to 0.1 dB
CRTN 1988, roadAnnex examples 2 to 183 of 30 dB0.01 dB
CRN 1995, railAppendix A2 examples 2 to 143 of 30.007 dB0.01 dB

What this does not show

We have not published a same-input benchmark against another commercial noise modelling package. A comparison only means something when traffic, geometry, calibration and output index are identical, so we will not quote one until that exists.

AURIS does not yet claim a formal ISO 17534 quality declaration. Validation records are issued by the developer, not a third party.

Built for UK practice first

Made for the reports you actually write.

AURIS is developed for the UK market first: the methods planning officers and Environmental Health ask for, in one model, with the people who build it a message away.

01

UK methods in one model

CRTN, CRN, BS 5228 and BS 4142 alongside ISO 9613-2:2024, sharing one site, one terrain and one set of receptors.

02

A direct line to the developers

Early-access consultancies report problems straight to the development team. Fixes arrive through the in-app updater, not next year’s release.

03

A native Mac app

Built for Apple silicon, not a browser tab or a remote desktop. A Windows installer is in preparation.

We use AURIS on our own planning work. We chose to distribute it because it shows its working: any ISO 9613-2 level can be opened up term by term, and the validation is published, including the case that does not match.
Polaris Acoustics, official AURIS distributor
Early access

Bring AURIS to your consultancy.

AURIS is opening to a small group of UK acoustic consultancies. Tell us about your team and the work you do, and Polaris Acoustics will be in touch.

Early access

Use AURIS on live projects ahead of general release.

Shape the roadmap

Your feedback goes straight to the development team.

Onboarding with us

A walkthrough on one of your own sites with Polaris Acoustics, the official distributor.

Register your interest

It takes under a minute. We never share your details.

Methods you use most
We will be in touch about early access.
Questions

AURIS, answered.

What is AURIS?

AURIS is environmental noise modelling software for acoustic consultants, officially distributed by Polaris Acoustics. It predicts sound levels from industry, roads, railways and construction across real terrain, buildings and barriers, then turns the results into receptor tables, 3D views and noise contour maps for planning reports.

Which calculation methods does AURIS use?

ISO 9613-2:2024 for outdoor sound propagation, the Calculation of Road Traffic Noise (CRTN), the Calculation of Railway Noise (CRN) and the BS 5228-1 Annex C construction plant library, with a workflow for BS 4142 assessments.

How is AURIS validated?

Every octave band of ISO/TR 17534-3 control examples T01 to T18 is checked to within ±0.5 dB as part of the release gate. CRTN Annex worked examples 2 to 18 and CRN Appendix A2 worked examples 2 to 14 run through the same code path consultants use. A separate in-house solver that cannot share AURIS code agrees on 15 benchmark scenarios to within 0.085 dB, and frozen reference results stop a release if they move.

Is AURIS certified to ISO/TR 17534-3?

ISO/TR 17534-3 provides control examples rather than a certificate. AURIS reproduces T01 to T18 within the ±0.5 dB result intervals. T19 differs by 2.23 dB at 250 Hz from the original 1996-based reference, which we publish rather than hide. AURIS does not yet claim a formal ISO 17534 quality declaration.

Who supplies AURIS?

Polaris Acoustics is the official distributor of AURIS. Polaris is a UK acoustic consultancy and uses AURIS on its own planning work.

Which platforms does AURIS run on?

AURIS is a native desktop app for Apple silicon Macs. A Windows installer is in preparation.

How can my consultancy get access?

AURIS is opening to a small number of UK acoustic consultancies. Register your interest on this page and Polaris Acoustics will be in touch about early access.

Polaris Acoustics

UK acoustic consultants for planning, development and environmental noise, and the official distributor of AURIS.

Early access

© 2026 Polaris Acoustics. AURIS is distributed by Polaris Acoustics.The demonstration site is fictional. Levels shown were calculated in AURIS.

Thank you.